Diagnostic Laboratories
High-throughput testing without operational friction.
Process hundreds or thousands of routine biochemistry, hematology, and clinical pathology samples daily with automated instrument interfacing and fast multi-channel dispatch.
MediNode Cloud LIS v4.2
https://lis.medinode.in/workbench
ONLINEHIGH THROUGHPUT
MediNode LISMain Reference Hub
Live Laboratory Workspace
Analyzers Connected (4/4)
Today's Samples
248
+14% vs yesterday
Processing
42
Avg TAT: 38 mins
Validation Queue
20
4 STAT urgent
WhatsApp Sent
186
98.4% delivered
Live Specimen Pipeline186 / 248 Completed (75%)
01 Reg
248
100% In
02 Collect
238
96% Barcoded
03 Process
218
Analyzers Sync
04 Validate
194
Pathologist Desk
05 Report
186
Dispatched
| Sample ID | Patient | Test Requisition | Priority | Status | Time |
|---|---|---|---|---|---|
SMP-89421 | Priya Sharma 29 / F | Lipid Profile + HbA1c Biochemistry | STAT | Processing | 10 mins ago |
SMP-89422 | Rajesh Kulkarni 52 / M | Complete Hemogram (CBC + ESR) Hematology | Routine | Validation | 24 mins ago |
SMP-89423 | Ananya Sen 28 / F | Thyroid Profile Total (T3/T4/TSH) Immunology | Urgent | Completed | 45 mins ago |
SMP-89424 | Vikram Malhotra 61 / M | Liver Function Test (LFT) Biochemistry | Routine | Collected | 52 mins ago |
Direct Machine Automation
Eliminate transcription errors from clinical analyzers.
Connect your 3-part/5-part hematology and clinical chemistry analyzers directly to MediNode LIS via ASTM E1381/E1394 and HL7 protocols.
MediNode Cloud LIS v4.2
https://lis.medinode.in/workbench
ONLINEASTM/HL7 SOCKETS
Bidirectional Analyzer Interface Gateway
Real-time ASTM E1381 & HL7 machine result ingestion engine
Gateway Engine Active (Port 5000/4000)
Sysmex XN-550
TransmittingAutomated Hematology
ASTM E1381 / E1394
TCP/IP • 192.168.1.104:5000
Processed Today:142 tests
Roche Cobas c311
OnlineClinical Biochemistry
HL7 v2.4 LIS2-A2
TCP/IP • 192.168.1.108:4000
Processed Today:218 tests
Mindray CL-900i
OnlineChemiluminescence Immunoassay
ASTM Protocol Bidirectional
Serial RS232 • COM3 (9600-8-N-1)
Processed Today:64 tests
Live ASTM/HL7 Socket Data Stream
Auto-Parser: ENABLEDZero Drop Loss
[10:14:02.102] RX [Sysmex XN-550]: H|^&|||MediNode|||||LIS||P|1
[10:14:02.145] RX: P|1|||VANCE^ELEANOR||19900412|F
[10:14:02.190] RX: O|1|89421001||^^^CBC|||||||A
[10:14:02.240] RX: R|1|^^^WBC|6.8|10*3/uL|4.0-10.0|N||F
[10:14:02.285] RX: R|2|^^^RBC|4.42|10*6/uL|3.8-5.2|N||F
[10:14:02.320] RX: R|3|^^^HGB|13.4|g/dL|12.0-15.5|N||F
[10:14:02.360] RX: R|4|^^^PLT|245|10*3/uL|150-450|N||F
[10:14:02.410] SYSTEM: Parsed 22 parameters for SMP-89421. Delta check PASS. Routed to Validation Queue.
Modern Laboratory Software
Unlock More Insights with Less Effort!
Learn how MediNode streamlines specimen intake, analyzer interfacing, delta-checks, and multi-channel patient reports.